BCI
3303
Hand-Held Pulse Oximeter
with Alarms & Memory (24 Hours)

The
BCI 3303 hand held pulse
oximeter incorporates a
visible and audible high/low alarm system to alert users to
changes in pulse rate and oxygen saturation percentage.
The BCI 3303 is
used during monitoring situations like minor surgery and stress
testing.
DISCONTINUED
THE BCI 3303 Offers:
-
Cost-effective,
portable, continuous, or spot check pulse oximetry
monitoring system with alarms and an internal rechargeable
battery.
-
Clinician,
Home-Use and Sleep Study modes make it ideal for use in the
hospital or clinical environment; during emergency air or
land transport; or for in-home use.
-
Battery charger included!
-
2
Year Manufacturer's Warranty on Oximeter.
-
1 Year
Manufacturer's Warranty on probe.
BCI 3303 Pulse Oximeter comes with:
BCI 3303 Pulse Oximeter Technical
Specifications:
Displays,
Indicators, & Keys:
SpO2: LED numeric display,
0.43 inch (10.9 mm) high
Pulse Rate: LED numeric display, 0.375 inch (9.5 mm) high
Pulse Strength: Logarithmically scaled, bar graph
Alarm Silence: LED flashes or lights to remind the user that
audio alarms are disabled
Sensor: LED flashes to alert the operator to check the SpO2
sensor placement
SpO2:
Range: 0-100% Accuracy: +/-2%
at 70-100%; +/-3% at 50-69%
Averaging: 4, 8, or 16 pulse beat average
Alarm Range:
High - 50%-100% & OFF (1%
steps)
Low - OFF & 50%-99% (1% steps)
Pulse Rate:
Range: 20-350 bpm
Accuracy: +/- 1 beat or 2% whichever is greater
Averaging: 8 or 16 second average
Resolution: 1 bpm
Alarm Range:
High - 20-350 & OFF (5 bpm
steps)
Low - OFF & 5-350 bpm (5 bpm steps)
Memory:
Spot checks and trends are
stored in tabular format for up to 99 patients and 24 hours of
run time.
Dimensions: 7.25" H x 3.3" W x 1.85" D (184 mm x 84 mm x 47 mm)
Weight: 19 oz. (539 grams)
Safety
Approvals:
Certified by TUV to IEC-601-1
CE (EMC), CSA 125, UL 544
Power
Requirements:
105-125V ~ 60 Hz
207-253V - 50 Hz (optional)
Battery Life:
Standard NiMH (Nickel Metal
Hydride) battery:
- Internal rechargeable: not user replaceable
- Fully charges in about 6 hours
- Approximately 24 hours of continuous use
- Low battery warning
Auxiliary
Serial Printer/Computer Output:
Data saved every thirty
seconds can be printed (trend).
Environmental Specifications:
Operating Temperature -4°F to
131°F (-20°C to 55°C)
Storage Temperature -40°F to 167°F (-40°C to 75°C)
Relative Humidity (non-condensing) 10-95% (storage) 15-95%
(operating)
Mechanical
Durability Test Results:
Vibration Testing: In
compliance with IEC 68-2-6; IEC 68-2-34
Shock Testing: In compliance with IEC 68-2-27
Drop Testing: Exceeded UL 544 testing recommendations
|